Chinese test plans for compressing or stacking a transport package on a compression tester usually cite GB/T 4857.4-2008. The standard has two modes: the compression test asks how much load the package can take, and the stacking test asks how long it can carry a given load. A plan that only says "stacking per GB/T 4857.4", without the mode, load, duration and pass/fail rule, cannot be reproduced and is hard to review. This guide covers how each mode is run; conditioning, initial load, platen speed and the hold; how results are recorded and judged; the contrast with ASTM D4169-23e1 Schedules B and C; and which accreditation mark SUNGO's Hefei laboratory can put on the report.
Key points
- GB/T 4857.4-2008 is an identical adoption of ISO 12048:1994 and has two modes. Compression test: load is applied until the package fails or a predetermined load or displacement is reached. Stacking test: a predetermined load is applied and held for a predetermined time, or until the package fails.
- Both modes use the same tester and require prior conditioning (ISO 12048 cites ISO 2233; the Chinese counterpart is GB/T 4857.2-2005). The standard sets requirements for platen speed, the initial load for deformation readings, and load stability during the hold.
- ISO 12048 (adopted as GB/T 4857.4) sets no stacking load, hold time or pass criterion (the national text governs if it adds any); fix all three in the plan beforehand.
- ASTM D4169-23e1 Schedule B (warehouse stacking) and Schedule C (vehicle stacking) use ASTM D642, calculate the load with an F factor, and remove it within 3 s of reaching the computed value. The GB/T 4857.4 stacking mode holds a predetermined load for a predetermined time. The two are not interchangeable.
- At Hefei SUNGO Medical Technology Co., Ltd. (the Hefei laboratory), GB/T 4857.4-2008 is in the CNAS scope (L24279) only, under the item name "stacking test", so reports carry the CNAS mark only. If you need an accredited result in the compression mode, confirm with the laboratory before ordering.
The standard and its scope
The details below come from China's national standards information platform (std.samr.gov.cn), checked on 2026-10-22:
| Item | Details |
|---|---|
| Number and title | GB/T 4857.4-2008, Packaging – Basic tests for transport packages – Part 4: Compression and stacking tests using a compression tester |
| Type and status | Recommended national standard, current; a test method standard under the National Technical Committee on Packaging (TC49) |
| Published / effective | 2008-05-27 / 2009-01-01; last reviewed 2025-03-27, conclusion "remains valid" |
| Relationship to ISO | Identical adoption (IDT) of ISO 12048:1994, Packaging – Complete, filled transport packages – Compression and stacking tests using a compression tester |
| Replaces | GB/T 4857.4-1992 (compression test method) and GB/T 4857.16-1990 (stacking test using a compression tester) |
The 2008 edition merged two earlier national standards, just as ISO 12048:1994 replaced the separate ISO 2872 (compression) and ISO 2874 (stacking using a compression tester).
Under Clause 1 of ISO 12048, the test item is a complete, filled transport package, and the test assesses its strength, or the protection it gives its contents, under compression. It can be run alone to study deformation, collapse or failure, or as part of a test sequence. The stacking test can also examine particular loading conditions, such as the bottom package of a stack resting on an open-decked pallet.
Because GB/T 4857.4-2008 adopts an ISO standard, the Chinese platform does not offer its full text. The method details below follow the ISO 12048:1994 text; for clause numbering and Chinese terminology, the GB/T 4857.4-2008 text governs. GB/T 4857.3-2008 (identical to ISO 2234:2000) applies a static load instead of a compression tester and is not within SUNGO's scope.
The two test modes
The principle in Clause 3 of ISO 12048 is simple: the package is placed between the platens of a compression tester and tested in one of two ways.
Mode 1: compression test
- Weigh the package and its contents separately, fill the package and measure the outside dimensions of the filled package.
- Place the package centrally on the lower platen in the predetermined attitude. Where the load should not act over the whole face, interpose suitable devices to simulate distribution conditions.
- Apply the load by relative movement of the platens at the specified speed, without peaks above the predetermined load, until the predetermined value is reached or the package collapses, whichever comes first. If it collapses first, record the load reached.
- If required, hold the predetermined load for a predetermined time or until collapse. If it collapses first, record the time elapsed.
- Remove the load and examine the package. If it has collapsed, measure its dimensions and check the contents for damage.
For loads applied to opposite edges or corners, follow the same steps on a tester whose platens are not free to tilt.
Mode 2: stacking test
Run the first three compression steps to reach the predetermined load, then hold it for the predetermined time or until collapse; if it collapses first, record the time elapsed. Examination after unloading is the same. A note in the standard prefers a tester with one fixed platen for stacking, and profiles representing particular loading conditions may be placed between platens and package.
| Aspect | Compression test | Stacking test |
|---|---|---|
| Question answered | How much load the package can take | How long the package can carry a given load |
| End point | Predetermined load or displacement reached, or failure | Predetermined load held for predetermined time, or failure |
| Recorded if failure occurs | Load at failure | Time to failure |
| Plan must specify | Predetermined load or displacement (not needed when testing to failure) | Predetermined load and hold time |
| Platens | Fixed platens for edge or corner loading | Tester with one fixed platen preferred |
Apparatus and loading requirements
- Platen speed: Clause 4.1 of ISO 12048 calls for a motor-driven, platen-type tester that moves one or both platens at a uniform relative speed of 10 mm/min ± 3 mm/min. Results at other speeds should not be compared with these, and metal drums or wooden crates may need lower speeds to avoid overshooting the predetermined load.
- Platens: flat, rigid, and large enough to cover the whole contact face of the package or interposed device. One platen stays horizontal throughout the test; the other is either rigidly mounted or held at its centre by a universal joint so that it can tilt in any direction.
- Holding the load: Clause 4.1.2 requires the tester to be able to hold the predetermined load for the predetermined time with fluctuation not exceeding ±4 % of that load, moving the platens no more than needed to keep the load. It serves both the stacking test and any hold in the compression test.
- Recording: the tester must record or indicate load and platen displacement; see the standard for the accuracy requirements.
The report must state whether the tester is mechanical or hydraulic and whether both platens were rigidly mounted. ASTM D642 notes that fixed-platen machines generally make corrugated boxes fail at their strongest point, and swivel-platen machines at their weakest. Fix the platen arrangement in the plan and keep it the same across rounds.
Conditioning, initial load and test specimens
Conditioning
Clause 6 of ISO 12048 requires conditioning to one of the sets of conditions in ISO 2233. The Chinese counterpart is GB/T 4857.2-2005, Part 2: Temperature and humidity conditioning (a modified adoption of ISO 2233:2000, reviewed on 2023-12-28 and kept valid). Paper-based materials respond to temperature and humidity, and ASTM D4169-23e1 Clause 11.1 also lists moisture content and temperature among the factors behind stacking loads, so the conditioning atmosphere and duration belong in the plan. Where conditions are critical, test in the conditioning atmosphere if possible, otherwise as close to it as practicable. The report records both atmospheres.
Initial load and deformation measurement
Unless otherwise specified, the first deformation reading (the datum point) is taken at an initial load chosen from Table 1 of the standard according to the expected average compression load. In practice this is often called a "preload"; the standard itself does not use that term or state a purpose for it. Informative Annex A gives an example: apply about 10 % of the predetermined load at the standard speed, take first measurements at chosen points, then apply and hold the predetermined load and repeat the measurements at set stages.
Specimens and attitude
Under Clause 5, the package is normally filled with its intended contents. Simulated or dummy contents may be used if their dimensions and physical properties are as close as possible to the real contents, and the normal closure method is still used. Test attitude is described with the part identification method of GB/T 4857.1-2019 (a modified adoption of ISO 2206:1987). Clause 7 recommends testing five replicate packages where possible.
Setting the load and judging the result
ISO 12048 (adopted identically as GB/T 4857.4) tells you how to apply a "predetermined load" for a "predetermined time" but not where those values come from; the national text governs if it adds anything. In practice the load is derived from unit mass, stack height and a combined factor by the method of the cited standard, and the plan should name that source.
- What the standard requires you to record: whether the package collapsed; the load at collapse or the time elapsed; observed changes in dimensions; a load/platen-displacement record if required; and the findings on the package and contents after unloading.
- Pass or fail: ISO 12048 gives no acceptance criteria, so they come from the plan. Typical criteria are no collapse during the hold, deformation within a limit set by the client, no damage to the contents, and an intact sterile barrier. ASTM D4169-23e1 Section 7 likewise requires acceptance criteria to be set before testing and lists three basic ones: product damage-free, package intact, or both.
Agree in advance how "failure" is identified: by the peak of the load-displacement curve, or by visible collapse, bulging or seal opening.
Comparison with ASTM D4169-23e1 Schedules B and C
Section 11 of ASTM D4169-23e1 covers Schedule B (warehouse stacking) and Schedule C (vehicle stacking), which determine whether the shipping unit can withstand compressive loads in storage or vehicle transport; the specified method is ASTM D642. Clause 11.1 lists what the load must account for: storage time, stacking pattern and alignment, container strength variability, moisture content, temperature, previous handling and transport, load support, and vibration. These are combined into an F factor, read from the Clause 11.2 table by construction type and assurance level (I, II, III), with the factors for Schedules B and C listed separately. For stacks of identical shipping units, Clause 11.3 gives L = M × J × F × (H − h)/h, where M is the mass of one unit, J is a unit conversion constant, H is the maximum stack height and h is the height of one unit. Clause 11.4 gives a separate calculation for vehicle stacking of mixed commodities in LTL or small-package environments.
Hold time is where the two are most often confused. Clauses 11.3 and 11.4 both require the load to be removed within 3 s of reaching the computed value. Schedules B and C do not simulate long-term stacking in the test; they fold storage time, moisture content, temperature and the other factors into the F factor and represent them with one higher load. Clause 6.1.2 adds that the F factors are based on testing in the standard atmosphere; for other atmospheres, the user must determine an appropriate compressive load factor.
| Aspect | GB/T 4857.4-2008 stacking mode | ASTM D4169-23e1 Schedules B/C |
|---|---|---|
| Role | Single test method | One schedule in a distribution cycle, run in sequence with the others on the same specimens |
| Test method | This standard | ASTM D642 |
| Source of the load | Given in the plan; ISO 12048 has no formula | Formula in Clause 11.3 or 11.4; F factor from Clause 11.2 |
| After reaching the load | Hold for the predetermined time or until failure | Remove within 3 s |
| Time and atmosphere effects | Captured by the hold time and conditioning | Folded into the F factor; user sets the factor for non-standard atmospheres |
If your plan cites D4169 Schedules B/C, calculate the load per D4169 and release it within 3 s; do not add a long hold. If your plan cites the GB/T 4857.4 stacking mode, it must give the predetermined load and the hold time.
Accreditation scope table
Rows from the Hefei laboratory's scopes; CNAS and CMA item names are translated from the Chinese certificates. The IAS certificate lists standards by number and title only (plus any exclusions), so the IAS rows show the printed title. IAS standards carry no year; confirm the edition before an IAS report is issued. ISO 12048 and ASTM D642 are not listed as separate standards in SUNGO's scopes.
| Item | Standard / clause | Notes / limitations |
|---|---|---|
| Stacking test | GB/T 4857.4-2008 (no clause listed) | Test object: transport packages; CNAS only (L24279) |
| Temperature and humidity conditioning test | GB/T 4857.2-2005 (no clause listed) | Test object: transport packages; only -40 °C to 150 °C; CNAS only |
| Schedule B warehouse stacking and Schedule C vehicle stacking | ASTM D4169-23e1, Clause 11 | Test object: transport packages not exceeding 150 lb (68 kg); CNAS |
| Conditioning | ASTM D4169-23e1, Clause 6 | Test object: transport packages not exceeding 150 lb (68 kg); only -40 °C to 150 °C; CNAS |
| Standard Practice for Performance Testing of Shipping Containers and Systems | ASTM D4169 (no year, no clause listed) | Certificate note: "Except for Schedule G, H"; Schedules B and C are not excluded; IAS (TL-1119) |
| Schedule C – vehicle stacking | YY/T 0681.15-2019, Clause 11 | Test object: packaged sterile medical devices; CNAS and CMA (no clause listed in the CMA schedule) |
| Test methods for sterile medical device package—Part 15: Performance testing of shipping containers and systems | YY/T 0681.15 (no year, no clause listed) | No exclusion noted on the certificate; IAS (TL-1119) |
Where SUNGO runs the test and under which accreditation
- Hefei laboratory: Hefei SUNGO Medical Technology Co., Ltd. (laboratory in Zipeng Town, Feixi County, Hefei, Anhui) holds CNAS L24279, CMA 260015342945 and IAS TL-1119. Shanghai SUNGO Medical Technology Co., Ltd. (laboratory at No. 958 Kangqiao East Road, Pudong, Shanghai; CNAS L22083, CMA 240015340087, IAS TL-1019) has no transport simulation standards in its scope. The two are separate legal entities, each reporting under its own certificates.
- Reports to GB/T 4857.4-2008: CNAS mark only. They cannot carry the CMA mark, and no IAS report can be issued. The CNAS certificate states that CNAS is a signatory to the ILAC and APAC mutual recognition arrangements. The certificate item is "stacking test"; if you need an accredited result in the compression mode, confirm with the laboratory first.
- If you need the CMA mark: neither GB/T 4857.4 nor ASTM D4169 is in the CMA scope. For sterile medical devices, consider basing the plan on YY/T 0681.15-2019 Schedule C. The CMA mark covers only the items listed in the CMA schedule, and the certificate states that it is valid within the People's Republic of China.
- If you need an IAS report: ASTM D4169 Schedules B/C or YY/T 0681.15 are options; confirm the edition before the report is issued.
- Whether a regulator or client accepts a given report is for them to decide; SUNGO makes no commitment on acceptance.
Preparing your samples and plan
- Specimens: complete, filled transport packages in shipping condition, with inner packaging, cushioning, outer case and closure method matching production. If you use dummy contents, describe how they differ from the real product.
- Quantity: the standard recommends five replicates where possible. For registration testing, set the sample size from the consequence of failure and the acceptable risk.
- Test plan: mode; predetermined load (or displacement) and its basis; hold time; attitude; any blocks or profiles simulating a pallet; platen arrangement; whether a load-displacement curve and deformation points are needed; acceptance criteria and how failure is identified.
- Package data: gross mass and mass of contents, outside dimensions, construction and materials, and how the packages are actually stacked in storage or transit.
- Conditioning: state the atmosphere and duration, and check that the temperature lies within the certificate limit of -40 °C to 150 °C. Confirm any special humidity requirement in advance.
- Report: state whether you need the CNAS, CMA or IAS mark. If vibration, drop or package integrity tests follow the stacking test, say so up front. Package integrity tests are outside the Hefei laboratory's scope; name the method and we will confirm which SUNGO company and accreditation apply, each company issuing its own report. See sterile packaging validation.
FAQ
What is the difference between the compression test and the stacking test in GB/T 4857.4?
The compression test loads to a predetermined load or displacement, or to failure, and records load. The stacking test holds a predetermined load for a predetermined time or until failure, and records time. Both use the same tester.
How long should the stacking load be held?
ISO 12048, which GB/T 4857.4 adopts, does not set a duration; it comes from the test plan or the product standard that cites the method. ASTM D4169-23e1 Schedules B/C, by contrast, remove the load within 3 s of reaching the computed value.
Can a GB/T 4857.4 report carry the CMA mark, or be issued as an IAS report?
No. At the Hefei laboratory, GB/T 4857.4-2008 is within the CNAS scope only. For sterile medical devices that need the CMA mark, consider a plan based on YY/T 0681.15-2019 Schedule C.
Our calculated stacking load is far above the weight of the packages above. Is that normal?
It depends on the plan's formula and factor. In D4169 the F factor combines storage time, stack alignment, strength variability, moisture content, temperature and vibration, so the computed load can far exceed the actual weight. Review the plan's basis; the laboratory applies the load the plan specifies.
When requesting a quote, please give the product and package construction, gross mass and dimensions, the intended standard and mode (GB/T 4857.4 compression or stacking, ASTM D4169 Schedules B/C, or YY/T 0681.15 Schedule C), the predetermined load and hold time or their basis, the conditioning atmosphere, the accreditation mark needed, and any follow-on tests. The Hefei laboratory will then confirm whether each item is within its scope. Send your request through our contact page, and see transport simulation testing for the service overview.
About SUNGO Lab: What We Test
SUNGO Lab is made up of two independent companies, Shanghai SUNGO Medical Technology Co., Ltd. and Hefei SUNGO Medical Technology Co., Ltd., and focuses on medical device testing. Our core service lines are:
- Wheelchair and mobility aid testing (Hefei laboratory): manual and powered wheelchairs, scooters, walking aids and crutches to the ISO 7176 series (excluding Part 19 crash testing and Part 20 standing wheelchairs), ANSI/RESNA WC-1/WC-2, EN 12183, EN 12184, the GB/T 18029 series and GB/T 12996-2024. Which accreditation (CNAS, CMA or IAS) covers each standard is as listed in our certificate scopes. See Wheelchair testing for FDA 510(k) and RESNA.
- Medical electrical safety and EMC (Hefei laboratory, IAS accredited, certificate TL-1119): IEC 60601-1, IEC 60601-1-2, IEC 60601-1-8, IEC 60601-1-11 and ISO 80601-2-69, with the corresponding Chinese standards GB 9706.1 and YY 9706.102.
- Testing for registration in China and overseas: we plan testing to the standards your target market requires (NMPA, FDA 510(k), EU CE marking and others) and issue the test reports for your submission; whether a report is accepted is decided by the regulator.
Our Shanghai laboratory also tests medical masks, gloves, surgical gowns, sterile packaging and sterilization-related items. CNAS and IAS are both signatories to the ILAC MRA. Send your product, target markets and standards through our contact page and we will confirm which laboratory and which accredited scope covers each test.