A test plan that says "drop per GB/T 4857.5" raises three questions at the drop tester: which corner is "corner 2-3-5", where drop height is measured from, and what the tester and impact surface must meet. GB/T 4857.5-1992 is an equivalent adoption of ISO 2248:1985, which says how to drop a package, not how high, how often or in what order, and gives no pass/fail criteria. This guide covers part numbering, drop attitudes, height measurement, equipment, conditioning and inspection, compares ISTA 2A and ASTM D4169 Schedule A, and explains which reports SUNGO's Hefei laboratory can issue. Drop height values are outside its scope.
Key points
- GB/T 4857.5-1992 is still current (confirmed at review on 2023-12-28) and is an equivalent adoption of ISO 2248:1985. The Hefei CNAS scope lists the 1992 edition.
- Parts are identified per GB/T 4857.1-2019, a modified adoption of ISO 2206:1987. Under ISO 2206, with a box in its transport position, the top is face 1, the right side 2, the bottom 3, the left side 4, the near end 5 and the far end 6. An edge is named by its two faces (e.g. 2-3) and a corner by its three faces (e.g. 2-3-5).
- ISO 2248 measures drop height from the package's lowest point at release to the nearest point on the impact surface. Height, count, sequence and attitudes come from whatever standard, procedure or plan calls up the method.
- The apparatus has four parts: lifting arrangement, holding means, release mechanism and impact surface. ISO 2248 quantifies impact surface mass, flatness and rigidity, attitude at release, height tolerance and impact velocity.
- ISO 2248 requires results to be recorded but does not judge them; acceptance criteria must be fixed in the plan beforehand.
- At the Hefei laboratory, GB/T 4857.5-1992 is within the CNAS scope (L24279) only. Reports carry the CNAS mark only: no CMA mark and no IAS report.
The standard and its scope
Data from China's National Public Service Platform for Standards Information, checked on 2026-10-22:
| Item | Details |
|---|---|
| Number and title | GB/T 4857.5-1992, Packaging – Transport packages – Vertical impact test method by dropping |
| Type and status | Recommended national standard, current, method standard; SAC/TC49 (packaging) |
| Issued / effective | 1992-02-13 / 1992-10-01; last reviewed 2023-12-28, "remains valid" |
| Replaces | GB 4857.5-1984 in full |
| Adoption | Equivalent adoption of ISO 2248:1985 |
ISO 2248:1985 is the second edition (1985-12-15) and, per the ISO catalogue, was confirmed at review in 2022. It covers vertical impact testing by dropping a complete, filled transport package, alone or within a test sequence for a distribution system with a vertical impact hazard (clause 1). The package is raised above a rigid plane surface and released to free-fall onto it, with atmosphere, drop height and attitude set in advance (clause 3).
The platform withholds the national standard's full text as it is ISO-based, so method details below come from ISO 2248:1985; as the adoption is equivalent, not identical, the Chinese text governs numbering, terminology and details.
Numbering faces, edges and corners
Drop attitudes are expressed using GB/T 4857.1-2019, effective 2019-12-01, which replaced the 1992 edition and is a modified adoption of ISO 2206:1987. The description below follows ISO 2206 clause 2; for placement and other details, the Chinese text governs.
Box-shaped packages
- Place the package in its intended transport position. If that is not known, ISO 2206 places the manufacturer's joint, if any, vertically on the observer's right; for this case, the GB/T 4857.1-2019 text governs.
- Number the faces with one side facing the observer, as in the table below.
- Number the edges by the two faces that meet there. Edge 1-2 is where the top meets the right side.
- Number the corners by the three faces that meet there. Corner 1-2-5 is where the top, right side and near end meet.
| Face | Position |
|---|---|
| 1 | Top |
| 2 | Side on the observer's right |
| 3 | Bottom |
| 4 | Side on the observer's left |
| 5 | Near end, facing the observer |
| 6 | Far end |
Each of a box's 12 edges and 8 corners then has a unique designation. With more than one manufacturer's joint, ISO 2206 recommends applying the same principle and choosing any side as face 5. Drop sequences and damage records use these numbers; mark them on the case before conditioning and photograph them to avoid misreading after turning.
Cylinders and sacks
- Cylinders: the ends of two perpendicular diameters on the upper surface are 1, 3, 5 and 7. The other ends of the lines through these points, parallel to the axis, are 2, 4, 6 and 8, and the lines are 1-2, 3-4, 5-6 and 7-8. A manufacturer's joint, if present, should be at 5-6.
- Sacks and bags: lay the sack on a face, sealed end toward the observer, with the side seam (if any) on the right or the longitudinal seam downward, and the filling end away. The upper face is 1, right side 2, lower face 3, left side 4, sealed end 5 and filling end 6.
- Other shapes: use a method derived from those above.
Positioning the three drop attitudes
The ISO 2248 annex expresses the predetermined attitude using this numbering. Where bungs, closures or fittings are present, the attitude at impact may be related to their position.
| Attitude | How to write it | Positioning (ISO 2248 Annex A.1, box-shaped packages) |
|---|---|---|
| Face drop | "face 3" | That face strikes the impact surface |
| Edge drop | "edge 2-3" | One of three: the angle between one face forming the edge and the impact surface; the centre of gravity vertically above the point of impact; or the two parallel edges nearest the impact edge in a horizontal plane |
| Corner drop | "corner 2-3-5" | One of two: the angles between two faces forming the corner and the impact surface; or the centre of gravity vertically above the point of impact |
For cylinders and sacks, the centre of gravity is always above the point, line, face, end or side of impact (sacks: face 1 or 3, end 5 or 6, side 2 or 4).
Clause 7.2 sets release tolerances. For face or edge drops, the impacting face or edge may be at most 2° from horizontal. For edge or corner drops, the angle between a prescribed surface and the horizontal must be within ±5° or ±10 % of that angle, whichever is greater. The plan should say which positioning method each edge and corner drop uses. Holding matters: an ISO 2248 footnote notes that a sack hung from the top may behave quite differently in an end drop from one supported underneath; the report must then say how it was held.
Measuring drop height, and who sets it
Under ISO 2248 clause 7.1, the package is held in its predetermined attitude at a height within ±2 % of the predetermined drop height. That height runs from the lowest point of the package at release to the nearest point on the impact surface. In an edge or corner drop, the lowest point is the edge or corner about to strike, so measure from there, not from the bottom face.
ISO 2248 sets no height. Height, number of drops, sequence and attitudes come from the product standard, test procedure or test plan that calls up GB/T 4857.5, usually depending on package weight, handling method and assurance level. For YY/T 0681.15-2019 Schedule A, follow that standard's text; for ASTM D4169-23e1, see 10.2.3. The plan should cite the source of the height rather than just saying "drop per GB/T 4857.5".
Drop tester, release mechanism and impact surface
Clause 4 of ISO 2248 divides the apparatus into four parts, which must also meet the clause 7 tolerances:
| Part | ISO 2248 requirement |
|---|---|
| Lifting arrangement (4.1) | Does not damage the package during lifting or release |
| Holding means (4.2) | Holds the package in its predetermined attitude before release |
| Release mechanism (4.3) | Releases the package so that no part of the apparatus obstructs its fall before impact |
| Impact surface (4.4) | Horizontal and flat, massive enough to be immovable, rigid enough not to deform under test conditions |
The note to 4.4 quantifies the impact surface for normal circumstances:
- integral with a mass at least 50 times that of the heaviest package to be tested;
- no two points on the surface differing in level by more than 2 mm;
- no more than 0.1 mm deformation when any 100 mm² area is loaded statically with 10 kg;
- large enough for the package to land entirely on it.
Impact velocity must be within ±1 % of free-fall velocity; an ISO 2248 footnote keeps the 1 % requirement where a completely free fall is not possible.
ISO 2248 prescribes no tester design. To review equipment, check three things: nothing obstructs the fall, the attitude at release is within the clause 7.2 tolerances, and impact velocity is close to free fall. A release that adds rotation, swing or a sideways push can take attitude and velocity outside these tolerances. The report must state the type of apparatus.
Sample preparation and conditioning
- Contents (ISO 2248 clause 5): normally the intended contents; simulated contents may be used if their dimensions and physical properties are as close as possible to the real ones. Close it as for normal distribution in either case.
- Conditioning (clause 6): one of the conditions in ISO 2233. The Chinese counterpart is GB/T 4857.2-2005, a modified adoption of ISO 2233:2000, confirmed as still valid on 2023-12-28.
- Test atmosphere (clause 7): where critical to the materials or use of the package, test in the conditioning atmosphere; otherwise as close to it as practicable. Board and cushioning may be humidity-sensitive, so put conditioning parameters and duration in the plan.
Inspection and acceptance
ISO 2248 clause 8 lists the report contents, including: number of replicates; description of the package, cushioning and closure; the contents (in full if simulated); gross and contents mass; conditioning and test atmosphere; attitude; drop height; type of apparatus; deviations; and the result with any helpful observations.
ISO 2248 does not decide pass or fail, so put acceptance criteria into the plan before testing:
- ASTM D4169-23e1 section 7 requires criteria to be set before testing and lists three common ones: product damage-free, package intact, or both.
- The ISTA 2A overview has the shipper decide in advance what counts as product damage, any allowable damage, how product condition is assessed and what package condition is acceptable.
- If a sterile device plan lists sterile barrier integrity as an acceptance criterion, those tests follow the transport tests; see sterile packaging validation.
Agree in advance whether packages are opened between drops. When ASTM D4169-23e1 is used as a performance test, section 4.1 requires the unit to stay unopened until the sequence is complete; opening it mid-sequence for development work may prevent evaluating the closure.
How ISTA 2A and ASTM D4169 Schedule A handle the drop
GB/T 4857.5 is a method standard; under ISO 2248, which it adopts, heights, counts and sequences come from the calling document. ISTA 2A and ASTM D4169 Schedule A have them built in. ISTA positions 2A, a partial simulation test, as a screening test for refining preliminary designs, not a predictor of shipping performance. Item 5 of its overview sequence is shock: drop, incline impact or horizontal impact, with drop height varying by weight. Its equipment table lists a free-fall drop tester (ASTM D5276) and also a shock test machine for vertical shock (ASTM D5487). (SUNGO's scope lists the ISTA 2A drop test as Test block 5.) In ASTM D4169-23e1 Schedule A, section 10.2 (manual handling) addresses impacts from dropping or throwing during loading, unloading, stacking, sorting or palletizing. It allows free-fall drops (D5276) or shock-machine drops (D5487), and 10.2.3 gives recommended heights by shipping weight and assurance level plus the number, sequence and orientation of drops. ASTM D5276 section 1.2 states that, for containers up to 110 lb (50 kg), it fulfils ISO 2206:1987 and ISO 2248:1985, though ISO procedures may not meet D5276. Follow whichever document the plan names; a stand-alone GB/T 4857.5 report cannot stand in for an ISTA 2A or D4169 report.
Accreditation scope
Rows from the Hefei laboratory's scopes; CNAS item names are translated from Chinese, IAS limitations quoted as written. The IAS scope cites no edition years, so confirm the edition before an IAS report. GB/T 4857.1, ISO 2248, ISO 2206, ASTM D5276 and ASTM D5487 are not listed as separate standards in SUNGO's scopes.
| Item | Standard / clause | Notes / limitations |
|---|---|---|
| Drop test | GB/T 4857.5-1992 (no clause listed) | Test object: transport packages; CNAS only (L24279) |
| Temperature and humidity conditioning test | GB/T 4857.2-2005 (no clause listed) | Test object: transport packages; only -40 °C to 150 °C; CNAS only |
| Drop test | ISTA 2A(11-22) Test block 5 | Test object: packages of 150 lb (68 kg) or less; CNAS |
| Partial (IAS scope) | ISTA 2A (no edition year, no clause listed) | Except for Incline Impact test and Horizontal Impact test; IAS (TL-1119) |
| Schedule A – manual handling | ASTM D4169-23e1 clause 10.2 | Test object: transport packages not exceeding 150 lb (68 kg); CNAS |
| Partial (IAS scope) | ASTM D4169 (no edition year, no clause listed) | Except for Schedule G, H; IAS (TL-1119) |
| Schedule A – manual handling | YY/T 0681.15-2019 clause 10 | Test object: sterile medical device packages; CNAS and CMA (no clause listed in the CMA schedule) |
| Whole standard (IAS scope) | YY/T 0681.15 (no edition year) | IAS (TL-1119) |
As the IAS scope excludes only Schedules G and H of ASTM D4169, Schedule A falls within it (our inference from the exclusion).
Where the work is done and under which accreditation
- Hefei laboratory: Hefei SUNGO Medical Technology Co., Ltd., Zipeng Town, Feixi County, Hefei (CNAS L24279, CMA 260015342945, IAS TL-1119). Shanghai SUNGO Medical Technology Co., Ltd. (laboratory at 958 Kangqiao East Road, Pudong; CNAS L22083, CMA 240015340087, IAS TL-1019) has no transport simulation standards in scope. The two are separate legal entities, each reporting under its own accreditations.
- GB/T 4857.5-1992 reports: CNAS mark only, no CMA mark and no IAS report. The CNAS certificate states that CNAS is a signatory to the ILAC and APAC arrangements. Conditioning to GB/T 4857.2-2005 is also CNAS only and limited to -40 °C to 150 °C.
- If you need the CMA mark: GB/T 4857 is not in the CMA scope. For sterile medical devices, consider YY/T 0681.15-2019 Schedule A as the basis. The CMA mark covers only items in the CMA schedule and, as the certificate states, is valid within the People's Republic of China.
- If you need an IAS report: ISTA 2A, ASTM D4169 Schedule A or YY/T 0681.15; confirm the edition first.
- ISTA 2A shock: the CNAS scope lists only the drop test for Test block 5, and the IAS scope excludes incline and horizontal impact, so at SUNGO only the drop method is available.
- ASTM D4169 Schedule A: the CNAS test object is transport packages not exceeding 150 lb (68 kg).
- Shock-machine drops (ASTM D5487): D4169-23e1 section 10.2 and the ISTA 2A overview both list this option, but D5487 is not a separately listed standard in SUNGO's scopes. If the plan calls for it, confirm with the laboratory before ordering whether this can be performed.
- Whether a regulator or client accepts a given report is their decision; SUNGO makes no commitment on acceptance.
Preparing samples and information
- Samples: complete, filled transport packages as shipped, with inner packaging, cushioning, outer case and closure matching production. Explain any differences if contents are simulated.
- Numbering reference: which face is up in transport and where the manufacturer's joint is; for cylinders and sacks, the sealed end. Send any existing numbering diagram.
- Test plan: the basis (GB/T 4857.5 alone, or ISTA 2A, ASTM D4169 or YY/T 0681.15), the drop height and its source, and the number, sequence and attitude of drops ("face 3", "edge 2-3", "corner 2-3-5"). Add the positioning method for edge and corner drops and the conditioning parameters.
- Package data: gross and contents mass, dimensions, structure and materials, cushioning and closure.
- Acceptance criteria: what counts as damage, whether packages are opened between drops, and any functional or package integrity tests afterwards.
- Quantity: as set by the test plan.
- Unusual packages: for large, heavy or irregular packages, confirm beforehand that the equipment can hold and position them.
- Report: state whether you need the CNAS, CMA or IAS mark.
FAQ
Does GB/T 4857.5 specify a drop height?
ISO 2248:1985 sets none; it defines only how height is measured and its tolerance (GB/T 4857.5 adopts it equivalently; the Chinese text governs). Height, count, sequence and attitudes come from the document that calls up the method.
Which corner is "corner 2-3-5"?
Under ISO 2206:1987 numbering (adopted with modifications in GB/T 4857.1-2019), it is where the right side (2), bottom (3) and near end (5) meet: the lower right corner on the side facing the observer.
Is drop height measured from the bottom of the box?
No. ISO 2248 clause 7.1 measures from the package's lowest point at release to the nearest point on the impact surface; in edge and corner drops, that is the edge or corner about to strike.
Can a GB/T 4857.5 report carry the CMA mark or be issued as an IAS report?
No. At the Hefei laboratory, GB/T 4857.5-1992 is within the CNAS scope only. Where a sterile device needs the CMA mark, consider basing the plan on YY/T 0681.15-2019 Schedule A.
Can the ISTA 2A shock test be run as an incline impact?
ISTA 2A allows drop, incline impact or horizontal impact. SUNGO's IAS scope excludes the last two and its CNAS scope lists only the drop test, so only the drop can be performed at SUNGO.
When requesting a quote, give the product and package construction, mass, dimensions and transport orientation; the intended basis (see the test plan item above); drop heights, count, sequence and attitudes or their source; conditioning; acceptance criteria; the accreditation mark you need; and any other tests. The Hefei laboratory will confirm which items fall within its accredited scope. Send your request via our contact page, or read more about transport simulation testing for medical devices.
About SUNGO Lab: What We Test
SUNGO Lab is made up of two independent companies, Shanghai SUNGO Medical Technology Co., Ltd. and Hefei SUNGO Medical Technology Co., Ltd., and focuses on medical device testing. Our core service lines are:
- Wheelchair and mobility aid testing (Hefei laboratory): manual and powered wheelchairs, scooters, walking aids and crutches to the ISO 7176 series (excluding Part 19 crash testing and Part 20 standing wheelchairs), ANSI/RESNA WC-1/WC-2, EN 12183, EN 12184, the GB/T 18029 series and GB/T 12996-2024. Which accreditation (CNAS, CMA or IAS) covers each standard is as listed in our certificate scopes. See Wheelchair testing for FDA 510(k) and RESNA.
- Medical electrical safety and EMC (Hefei laboratory, IAS accredited, certificate TL-1119): IEC 60601-1, IEC 60601-1-2, IEC 60601-1-8, IEC 60601-1-11 and ISO 80601-2-69, with the corresponding Chinese standards GB 9706.1 and YY 9706.102.
- Testing for registration in China and overseas: we plan testing to the standards your target market requires (NMPA, FDA 510(k), EU CE marking and others) and issue the test reports for your submission; whether a report is accepted is decided by the regulator.
Our Shanghai laboratory also tests medical masks, gloves, surgical gowns, sterile packaging and sterilization-related items. CNAS and IAS are both signatories to the ILAC MRA. Send your product, target markets and standards through our contact page and we will confirm which laboratory and which accredited scope covers each test.