EN 13795-2:2025 Clean Air Suit Testing: 5 Requirements, Methods and Limits

EN 13795-2:2025 Clean Air Suit Testing: 5 Requirements, Methods and Limits

EN 13795-2:2025 is the part of the European EN 13795 surgical clothing and drapes series that covers clean air suits. Its Table 1 requires five clean air suit tests: microbial penetration (dry), microbial cleanliness (bioburden), particle release (linting), bursting strength (dry) and tensile strength (dry), at standard or high performance. Below we cover Table 1, how each method works and reports results, and how Part 2 differs from Part 1 for gowns and drapes.

Key points

  • Five tests, each with a set method. The five characteristics in Table 1 are tested to EN ISO 22612:2005, EN ISO 11737-1:2018, EN ISO 9073-10:2004, EN ISO 13938-1:2019 and EN ISO 9073-3:2023, as specified in Annex A, clauses A.2.1 to A.2.5.
  • The two levels differ on one line only. Standard and high performance differ only for dry microbial penetration (≤ 100 CFU versus ≤ 50 CFU). The other four requirements are the same for both levels.
  • No wet or liquid barrier requirements. Part 2 does not cite EN ISO 22610 (wet bacterial penetration) or EN ISO 811 (hydrostatic pressure) as normative references, and it has no critical and less critical product areas.
  • Material tests are not the whole story. Clause 4 requires compliance throughout the useful life and says design must also be considered: closed arm and foot openings, and a barrier hood should be worn.
  • SUNGO Shanghai's CNAS scope covers the five items. Shanghai SUNGO Medical Technology Co., Ltd. has all five in its CNAS schedule and EN 13795-2 (no year) in its IAS scope; CMA does not cover it, and the Hefei laboratory's scope does not include clean air suits.

EN 13795-2:2025 scope: what counts as a clean air suit

Clause 1 covers single-use and reusable clean air suits used as medical devices for clinical staff, intended to prevent the transmission of infective agents between clinical staff and patients during surgical and other invasive procedures. It sets test methods and performance requirements, plus manufacturing and processing information to be supplied to users and third-party verifiers in addition to the usual labelling (see EN ISO 20417 and EN ISO 15223-1).

The Introduction adds that clean air suits limit the spread of infective agents to patients, surgical sites and equipment by preventing operating room staff from dispersing bacteria-carrying skin scales, helping prevent post-operative surgical site infections. In infection-prone invasive operations they help reduce infection risk together with ventilation and correct working methods. Key definitions from Clause 3:

  • A clean air suit is a suit used as a working garment, intended and shown to minimize contamination of the operating room air from skin scales shed by the wearer.
  • It consists of a coverall, or a blouse and a pair of trousers, and can also include a barrier hood.
  • A scrub suit does not need to meet clean air suit requirements; it is not primarily intended to prevent airborne dispersal from staff, and its design and processing are left to the manufacturer.
  • Particle release is the release of fibre fragments and other particles under mechanical stress that simulates handling and use. Dry penetration is microbial penetration in the dry state caused by air movement combined with mechanical action by vibration.

Edition and harmonisation, briefly: EN 13795-2:2025 was prepared by CEN/TC 205, approved by CEN on 29 December 2024 and supersedes EN 13795-2:2019. Commission Implementing Decision (EU) 2025/2078, published in the Official Journal on 20 October 2025 and in force from that day, added EN 13795-2:2025 as entry 34 in the Annex to Implementing Decision (EU) 2021/1182. As checked on 13 November 2026, the GOV.UK consolidated list of designated standards for medical devices (version 2, 17 January 2026; applies to England, Scotland and Wales) still lists EN 13795-2:2019. For the Part 1 edition changes and how to assess existing reports, see EN 13795-1:2025 vs 2019: Surgical Gown and Drape Changes and Existing Reports; that topic is not repeated here.

EN 13795-2:2025 Table 1: the five requirements and their limits

Clause 4 states that, to comply, products shall meet all requirements of the document, including Table 1, when tested according to Annex A throughout their useful life. The table below follows Table 1 of the 2025 edition, in the original order:

CharacteristicTest methodAnnex A clauseUnitStandard performanceHigh performance
Microbial penetration, dryEN ISO 22612:2005A.2.5CFU≤ 100 (see note)≤ 50 (see note)
Microbial cleanliness (bioburden)EN ISO 11737-1:2018A.2.1CFU/100 cm²≤ 100≤ 100
Particle release (linting)EN ISO 9073-10:2004A.2.2log10 (lint count)≤ 4.0≤ 4.0
Bursting strength, dryEN ISO 13938-1:2019A.2.3kPa≥ 40≥ 40
Tensile strength, dryEN ISO 9073-3:2023A.2.4N≥ 20≥ 20

Note: test conditions for dry microbial penetration are a challenge concentration of 10⁸ CFU/g talcum and 30 min vibration time.

Two more points. First, the normative reference to EN ISO 11737-1:2018 is marked as impacted by A1:2021, and the normative references also include EN ISO 139:2005 on standard atmospheres for conditioning and testing (marked as impacted by A1:2011). Second, Clause 4 requires the biocompatibility of the product to be evaluated in accordance with EN ISO 10993-1:2020; this is not a Table 1 item. Biological tests are not within SUNGO's accreditation scope and SUNGO does not perform them itself. Where such tests are needed, they can be subcontracted to a suitably qualified laboratory with the client's prior consent, and the subcontracted items and the subcontractor are stated in the report.

Standard performance or high performance

In Part 2, performance levels reflect the operating room microbial cleanliness the procedure requires. A note to the definition of high performance gives as an example infection-prone clean procedures where operating room air counts of ≤ 10 CFU/m³ are required. Decide which level you will claim before testing, because that fixes the pass threshold for dry penetration. Annex D (informative) explains performance levels and gives users guidance on selecting products.

How the five clean air suit test methods work

The descriptions below follow the method standards. Annex A of EN 13795-2 sets its own rules on sampling, number of specimens and treatment of results; refer to the original text.

Dry microbial penetration: EN ISO 22612:2005

Each test piece is fixed in a stainless steel container and talc contaminated with Bacillus subtilis spores is poured onto it; one container is left uncontaminated as a control. A sedimentation plate sits a short distance below each test piece. The apparatus is vibrated by a pneumatic ball vibrator, talc that penetrates falls onto the plates, and the plates are incubated and the colonies counted. The method's introduction notes that the particles are in the size range most typical for human skin scales, which is what a clean air suit is meant to hold back.

ISO 22612 provides two challenge concentrations and two vibration times and leaves the choice to the product standard. EN 13795-2:2025 sets 10⁸ CFU/g talcum and 30 min in the note to Table 1. Clause 5 of ISO 22612 specifies conditioning and testing at (20 ± 2) °C and (65 ± 5) % relative humidity; where EN 13795-2 Annex A sets its own conditioning, the original text applies. Results are expressed in CFU; a lower count means better resistance to bacteria-carrying particles. A note in the ISO 22612 scope says the method is too complex for routine quality control but may suit compliance assessment.

Microbial cleanliness: EN ISO 11737-1:2018

EN ISO 11737-1 covers enumeration and characterization of the population of viable microorganisms (the bioburden) on or in a health care product, component, raw material or package. Microorganisms are removed from the specimen, cultured and counted. Because removal is never complete and some microorganisms may fail to grow, a bioburden correction factor compensates, and informative Annex C gives guidance on validating recovery efficiency. EN 13795-2 Table 1 expresses the result as CFU per 100 cm².

Particle release (linting): EN ISO 9073-10:2004

This is a modified Gelbo Flex method. The test piece is clamped in tubular form between two circular plates; one is fixed and the other moves to and fro while rotating back and forth, twisting and compressing the specimen. Air is drawn from the chamber into a particle counter that counts and sizes the particles; depending on the counter, the size range runs from 0.3 µm or 0.5 µm up to 25 µm. The test runs under a vertical laminar flow hood to keep background particles out.

The standard defines the coefficient of linting as the log of the particle count, and EN 13795-2 Table 1 gives the unit as log10 (lint count). A fabric that sheds a lot of lint could itself become a particle source in the operating room.

Bursting strength, dry: EN ISO 13938-1:2019

This is the hydraulic method. The specimen is clamped over an expansive diaphragm, and fluid is pumped in under the diaphragm at a constant rate until the specimen bursts. Bursting strength is the mean bursting pressure minus the diaphragm pressure (the pressure needed to distend the diaphragm alone to the same distension). Results are in kPa. The method applies to knitted, woven, nonwoven and laminated fabrics and can test conditioned or wet specimens; EN 13795-2 requires the dry state only.

Tensile strength, dry: EN ISO 9073-3:2023

This is a strip method. A specimen is extended at a constant rate on a constant-rate-of-extension (CRE) tensile tester until it ruptures, recording maximum force and elongation at maximum force, plus force and elongation at rupture where required. The standard offers two specimen widths: Option A at 25 mm and Option B at 50 mm. Which option and which directions EN 13795-2 Annex A calls for should be checked against the original text. Results are in N, and Table 1 requires the dry state only.

For reference, the 2019 edition of Part 2 cited EN 29073-3:1992 (tensile) and EN ISO 13938-1:1999 (bursting); the 2025 edition cites EN ISO 9073-3:2023 and EN ISO 13938-1:2019. With 2019-edition reports, first check which method edition was used.

EN 13795-2 vs EN 13795-1: what is different

Both parts share one framework: testing is set out in normative Annex A, there are two performance levels (standard and high), and both introductions aim at the same level of safety from single-use and reusable products throughout their useful life. But the Table 1 requirements for clean air suits cover the dry state only. Comparing the Introduction and Clauses 2 and 3 in the public previews of both 2025 parts:

AspectEN 13795-1:2025 (surgical gowns and drapes)EN 13795-2:2025 (clean air suits)
Main purposeMinimize the spread of infective agents to and from patients' operating woundsPrevent dispersal of bacteria-carrying skin scales from operating room staff
Product areasCritical and less critical product areas are definedNo product areas
What drives the performance levelDuration, mechanical stress and liquid challengeMicrobial cleanliness of the operating room required for the procedure
Wet bacterial penetrationCites EN ISO 22610:2006Not cited
Resistance to liquid penetration (hydrostatic pressure)Cites EN ISO 811:2018Not cited
Bursting and tensile strengthDry and wet (per the item names for EN 13795-1:2025 A 2.4 and A 2.5 in SUNGO's CNAS schedule)Dry only in Table 1
Methods cited by both partsEN ISO 22612:2005, EN ISO 11737-1:2018, EN ISO 9073-10:2004, EN ISO 13938-1:2019, EN ISO 9073-3:2023Same as left

In testing terms: assessing a clean air suit against EN 13795-2 does not involve wet bacterial penetration or hydrostatic pressure, and all five Table 1 items must be met. Because the tables, levels and pass criteria differ, a Part 1 conclusion cannot simply stand in for a Part 2 conclusion.

Design matters too

Right after Table 1, Clause 4 notes that the Table 1 methods are materials tests and that design must also be considered. With a tight material, bacteria escape through the openings for head, arms and feet, so arm and foot openings shall be closed; a barrier hood should be worn and tucked into the neckline; and a blouse should be tucked into the trousers or have a tightly fitting waist. Annex E covers design and the source strength concept, the average number of bacteria-carrying particles (CFU) emitted per second by a person wearing a specified garment during a certain activity in a specified environment. These are design matters, not Table 1 tests.

SUNGO accreditation scope for EN 13795-2:2025

Transcribed from the CNAS schedule (L22083) and IAS scope (TL-1019) of Shanghai SUNGO Medical Technology Co., Ltd.:

ItemStandard and clauseNotes / limitations
Clean air suits: microbial penetration, dryEN 13795-2:2025 A 2.5CNAS; no limitation stated. Method standard EN ISO 22612:2005 is listed under the surgical gowns and drapes entry
Clean air suits: cleanliness, microbialEN 13795-2:2025 A 2.1CNAS; no limitation stated. Method standard EN ISO 11737-1:2018+A1:2021 is listed under the surgical gowns and drapes entry
Clean air suits: lintingEN 13795-2:2025 A 2.2; EN ISO 9073-10:2004CNAS; no limitation stated
Clean air suits: bursting strength, dryEN 13795-2:2025 A 2.3; EN ISO 13938-1:2019CNAS; no limitation stated
Clean air suits: tensile strength, dryEN 13795-2:2025 A 2.4; EN ISO 9073-3:2023CNAS; no limitation stated
Whole standardEN 13795-2IAS; no year stated. Confirm the edition with the laboratory before an IAS report is issued against a specific edition
Whole standardEN ISO 9073-3; EN 29073-3; ISO 11737-1IAS; no year stated

The CNAS schedule writes clause numbers as "A 2.1" and so on, corresponding to A.2.1 to A.2.5 in Annex A of the standard. The CNAS schedule lists only the 2025 edition of EN 13795-2. Neither EN 13795-2 nor the EN ISO methods above are in the Shanghai CMA schedule.

Where SUNGO does this work and under which accreditation

  • Testing entity: Shanghai SUNGO Medical Technology Co., Ltd., laboratory at No. 958 Kangqiao East Road, Pudong New Area, Shanghai. Hefei SUNGO Medical Technology Co., Ltd. is a separate legal entity whose scope does not include clean air suits.
  • CNAS (L22083): the five EN 13795-2:2025 items above are in scope; CNAS reports can be issued against the 2025 edition.
  • IAS (TL-1019): EN 13795-2 is listed as a whole standard without a year; confirm the edition with the laboratory before ordering. CNAS and IAS are both signatories to the ILAC MRA.
  • CMA (240015340087): covers only items in its schedule and is valid only within the People's Republic of China. EN 13795-2 is not in the schedule, so no CMA report can be issued.
  • Biological tests are outside SUNGO's accreditation scope; where needed they are handled by subcontracting as described above. Whether a notified body or an overseas regulator accepts a given report is up to that body.

The full scope of both sites is summarized in SUNGO Medical Device Testing Scope: CNAS, CMA and IAS in Shanghai and Hefei. Surgical gown related testing services are on the surgical gown testing service page.

Preparing clean air suit samples

  • Product configuration: coverall or blouse and trousers, with or without a barrier hood; describe each component if materials or layers differ.
  • Claimed performance level: standard or high performance, which decides the pass threshold for dry microbial penetration.
  • Single-use or reusable: for reusable suits, describe the laundering and sterilization process and the claimed useful life. Table 1 must be met throughout the useful life, and Clause 5 requires manufacturers and processors to document that requirements are met and that fitness for the intended purpose is established for each use; for reusable products, effects of clinical use must be considered in addition to processing.
  • Sample form: finished garments or fabric. Sampling locations, number of specimens and treatment of results follow Annex A; please confirm with the laboratory in advance the quantity to send and the state of samples for microbial cleanliness (packaged or not, processed or not).
  • Report needs: a CNAS report (EN 13795-2:2025) or an IAS report (edition to be confirmed in advance); and whether the target market is the EU or Great Britain, since the EU list of harmonised standards and the UK list of designated standards give different editions.
  • Existing documents: send full copies of any 2019-edition or gown reports so the method basis can be checked.

FAQ

Do EN 13795-2 clean air suits need hydrostatic pressure or wet bacterial penetration tests?

No. Table 1 of the 2025 edition has only five dry-state characteristics, and EN ISO 811 and EN ISO 22610 are not normative references. Those tests belong to Part 1 for gowns and drapes.

What is the difference between high and standard performance clean air suits?

Only dry microbial penetration: ≤ 100 CFU for standard performance and ≤ 50 CFU for high performance, under the same test conditions. The other four requirements are the same at both levels.

Are the EN 13795-2:2025 limits the same as in the 2019 edition?

The four significant technical changes listed in the 2025 foreword (clarified testing specifications and reporting, an expanded Annex C on environmental impact, alignment with Regulation (EU) 2017/745, and updated references) do not include a revision of performance requirements, but the method references for tensile and bursting strength were updated. Whether the two Table 1 versions match line by line should be checked against the 2019 original.

Can an EN 13795-2 clean air suit test report carry the CMA mark?

No. EN 13795-2 is not in SUNGO Shanghai's CMA schedule. You can choose a CNAS report (five items) or an IAS report (whole standard, edition confirmed in advance).

We already have an EN 13795-1 report for our gowns. Do clean air suits still need testing to Part 2?

To claim conformity with EN 13795-2, a clean air suit is assessed against Part 2 Table 1 and its performance levels. Where the fabric is the same, whether existing data can be referenced depends on the notified body or the client.

To arrange EN 13795-2:2025 testing for clean air suits, send the product configuration, materials, claimed performance level, single-use or reusable status and target market, and say whether you need a CNAS or IAS report. Submit quotation requests through the contact page.

About SUNGO Lab: What We Test

SUNGO Lab is made up of two independent companies, Shanghai SUNGO Medical Technology Co., Ltd. and Hefei SUNGO Medical Technology Co., Ltd., and focuses on medical device testing. Our core service lines are:

  • Wheelchair and mobility aid testing (Hefei laboratory): manual and powered wheelchairs, scooters, walking aids and crutches to the ISO 7176 series (excluding Part 19 crash testing and Part 20 standing wheelchairs), ANSI/RESNA WC-1/WC-2, EN 12183, EN 12184, the GB/T 18029 series and GB/T 12996-2024. Which accreditation (CNAS, CMA or IAS) covers each standard is as listed in our certificate scopes. See Wheelchair testing for FDA 510(k) and RESNA.
  • Medical electrical safety and EMC (Hefei laboratory, IAS accredited, certificate TL-1119): IEC 60601-1, IEC 60601-1-2, IEC 60601-1-8, IEC 60601-1-11 and ISO 80601-2-69, with the corresponding Chinese standards GB 9706.1 and YY 9706.102.
  • Testing for registration in China and overseas: we plan testing to the standards your target market requires (NMPA, FDA 510(k), EU CE marking and others) and issue the test reports for your submission; whether a report is accepted is decided by the regulator.

Our Shanghai laboratory also tests medical masks, gloves, surgical gowns, sterile packaging and sterilization-related items. CNAS and IAS are both signatories to the ILAC MRA. Send your product, target markets and standards through our contact page and we will confirm which laboratory and which accredited scope covers each test.

Need testing? Tell us your product and standards

Contact us directly
Phone
+86 132 4819 8029 (Mr. Gan)+86 177 5560 4650 (Mr. Luo)
E-mail
haixiao.gan@sungoglobal.comjun.luo@sungoglobal.com
Mon–Fri 9:00-18:00
WeChat QR CodeWeChatScan to add us on WeChat
Send us a message
About your personal information
  • Who collects it: Shanghai SUNGO Medical Technology Co., Ltd., the operator of this website. If the work you ask about is carried out by Hefei SUNGO Medical Technology Co., Ltd., we pass your enquiry to that company’s contact person for the same purpose.
  • What we collect: only what you type into the form above. The website’s access logs routinely record IP address and browser type, used only for security, troubleshooting and traffic statistics. Please do not enter ID numbers, medical records or other sensitive information.
  • Why: to reply to this testing enquiry. It is not used for bulk marketing; except for passing it to Hefei SUNGO Medical Technology Co., Ltd. as described above, it is not given to anyone else.
  • How long: 12 months from the day you submit it, then it is deleted. It is stored on a server in mainland China.
  • Your rights: contact us by the phone numbers or e-mail addresses above at any time to see, correct or delete what you submitted.