EN 13795-1:2025 vs 2019: Surgical Gown and Drape Changes and Existing Reports

EN 13795-1:2025 vs 2019: Surgical Gown and Drape Changes and Existing Reports

EN 13795-1:2025 has replaced EN 13795-1:2019, and Part 2 (clean air suits) was revised at the same time. Most manufacturers shipping surgical gowns, drapes and clean air suits to the EU hold reports issued against the 2019 editions, and they ask two questions: what changed, and do the reports need to be repeated? This guide answers only those questions. It draws on the European forewords of both editions, the clause text visible in the public previews (for 2025: cover, contents, foreword, introduction, Clauses 1 to 3 and the start of Clause 4; the 2019 Part 1 preview ends at Clause 2), and the status published by the EU and the UK government, all checked on 22 October 2026.

Key points

  • The 2025 edition formally replaces the 2019 edition. CEN approved it on 29 December 2024; it is dated January 2025, supersedes EN 13795-1:2019 and lists five significant technical changes, a) to e).
  • It is harmonised under the EU MDR. Implementing Decision (EU) 2025/2078, published and in force on 20 October 2025, adds EN 13795-1:2025 and EN 13795-2:2025 to Implementing Decision (EU) 2021/1182 as entries 33 and 34. The 2019 editions were harmonised under Directive 93/42/EEC by (EU) 2020/437, not under the MDR.
  • The changes that affect testing concern bursting and tensile strength. Wet bursting specimens are now prepared according to EN ISO 13938-1:2019 instead of EN 29073-3:1992; the bursting method moves from the 1999 to the 2019 edition; the tensile method changes from EN 29073-3:1992 to EN ISO 9073-3:2023.
  • No other method edition changes were found: EN ISO 22612:2005, EN ISO 22610:2006, EN ISO 811:2018 and EN ISO 9073-10:2004. Microbial cleanliness still cites EN ISO 11737-1:2018, now with a footnote referring to A1:2021.
  • No revision of performance requirements is listed. Critical and less critical areas and standard and high performance remain. The values in Tables 1 and 2 are not in the previews, and this guide quotes none.
  • Start with a gap assessment. Consider retesting tensile strength (dry and wet) and wet bursting strength first; check the other reports against Annex A of the 2025 edition. Acceptance is for the notified body or customer to decide.
  • SUNGO Shanghai: the CNAS schedule lists seven EN 13795-1:2025 items and five EN 13795-2:2025 items (2025 editions only); the IAS scope lists EN 13795-1 and EN 13795-2 as whole standards without a year; neither is in the CMA schedule.

The standard and its scope

The two editions at a glance

ItemEN 13795-1:2019EN 13795-1:2025
Approved by CEN24 October 201829 December 2024
Document dateApril 2019January 2025
SupersedesEN 13795:2011+A1:2013 (with EN 13795-2:2019)EN 13795-1:2019
Latest national adoption and withdrawal dateOctober 2019July 2025
Annex ZADirective 93/42/EEC essential requirementsRegulation (EU) 2017/745 general safety and performance requirements
EU Official Journal(EU) 2020/437, entry 130(EU) 2025/2078, entry 33 of (EU) 2021/1182
BSI editionBS EN 13795-1:2019, published 30 April 2019BS EN 13795-1:2025, published 28 February 2025; supersedes BS EN 13795-1:2019, which is withdrawn

Both were prepared by CEN/TC 205 "Non-active medical devices". EN 13795-2:2025 has the same dates and supersedes EN 13795-2:2019.

What changed in the scope

The core of Clause 1 is unchanged: information on manufacturing and processing for users and third-party verifiers, the characteristics of single-use and reusable gowns and drapes, and the test methods and performance requirements, all aimed at preventing transmission of infective agents between clinical staff and patients. Neither edition covers incision drapes or films or sets requirements for antimicrobial treatments. Two things differ in Clause 1, and one in the introduction:

  • The labelling reference changes from EN 1041 to EN ISO 20417 (EN ISO 15223-1 stays).
  • Laser: 2019 said it does not cover laser penetration requirements and pointed to EN ISO 11810 in the body text; 2025 says it includes no information on laser penetration and moves the EN ISO 11810 pointer into a note limited to drapes for which laser resistance is claimed.
  • The introduction now refers to the MDR general safety and performance requirements instead of the Directive 93/42/EEC essential requirements. On PPE, the 2019 text mentions Directive 89/686/EEC or Regulation (EU) 2016/425; the 2025 text keeps only the Regulation. Neither gives specific guidance for dual-use gowns.

Status in the EU and the UK

EU: Decision (EU) 2025/2078 was adopted on 17 October 2025. Its recitals say CEN and CENELEC revised the 2019 editions under a standardisation request and that the 2025 editions satisfy the MDR requirements they aim to cover. Presumption of conformity applies from the date the reference is published.

UK: on 22 October 2026, the gov.uk page "Designated standards: medical devices" showed a last update of 17 January 2026. The complete list in notice 0129/26 shows EN 13795-1:2019 and EN 13795-2:2019 (entries 136 and 137), and the page states that it applies to England, Scotland and Wales, i.e. Great Britain. For Great Britain, confirm the edition with your UK Approved Body or customer. For Northern Ireland, the national foreword of BS EN 13795-1:2025 states that Annex ZA and references to EU legislation remain valid.

Clause-by-clause comparison

The five changes in the foreword

  1. a) clarification of testing specifications and reporting of results;
  2. b) wet bursting specimens prepared according to EN ISO 13938-1:2019, no longer according to EN 29073-3:1992;
  3. c) former Annex D "Environmental aspects" expanded to cover environmental impact and circular economy, now "Environmental impact";
  4. d) alignment with Regulation (EU) 2017/745, including Annex ZA;
  5. e) updated normative references and bibliography.

The 2019 foreword had listed 17 changes, including moving clean air suits to Part 2, merging particulate cleanliness and linting into "particle release", and rewriting Annex A. The 2025 list is short and contains no revision of performance requirements.

Test method references

Only references used for performance testing are shown. The two 2019 Part 1 references for microbial penetration are outside the preview; their years are taken from the BSI product page reference list. That list is a BSI catalogue mapping, not the Clause 2 text (it lists EN ISO 9073-10:2004 as ISO 9073-10:2003, for example), so check the designation prefix in the standard.

Characteristic20192025Change
Microbial cleanlinessEN ISO 11737-1:2018EN ISO 11737-1:2018, as impacted by A1:2021Footnote added
Particle releaseEN ISO 9073-10:2004EN ISO 9073-10:2004None
Liquid penetrationEN ISO 811:2018EN ISO 811:2018None
Bursting strength, dry and wetEN ISO 13938-1:1999EN ISO 13938-1:2019, also for wet preparationEdition updated; wet preparation changed
Tensile strength, dry and wetEN 29073-3:1992EN ISO 9073-3:2023Method replaced
Dry microbial penetration22612:2005 (outside preview; check the standard)EN ISO 22612:2005No edition change found (2019 text not checked)
Wet microbial penetration22610:2006 (outside preview; check the standard)EN ISO 22610:2006No edition change found (2019 text not checked)
ConditioningEN ISO 139:2005EN ISO 139:2005None

The two method standards

EN ISO 9073-3:2023 (tensile). ISO 9073-3:2023, second edition, June 2023, replaces ISO 9073-3:1989 and is technically revised. Its foreword lists a new title, a new Terms and definitions clause with renumbering, and a revised 8.2. It is a strip test for nonwovens in the conditioned or wet state, with Option A (25 mm wide specimens) and Option B (50 mm), using constant-rate-of-extension (CRE) testers; constant-rate-of-loading (CRL) instruments are covered only for information in ISO 2062:2009, Annex A, and can be used by agreement. EN ISO 9073-3:2023 supersedes EN 29073-3:1992. The revised 8.2 is the laboratory sample (sampling) clause; the exact difference from 1989 has to be checked against both texts.

EN ISO 13938-1:2019 (bursting). ISO 13938-1:2019, second edition, November 2019, is described as a minor revision of the 1999 edition; the only listed change is updated normative references. It is a hydraulic method for knitted, woven, nonwoven and laminated fabrics, conditioned or wet.

So the bursting method has barely changed, but EN 13795-1:2025 changes how wet specimens are prepared, and the tensile method has been replaced. These are the two areas to focus on.

Terms and definitions

The 2025 Clause 3 has 17 entries, worded as follows (the 2019 Part 1 Clause 3 is not in the previews, so only the 2019 contents and Part 2 can be compared):

  • "Microbial cleanliness" (3.6), noted as often called "bioburden"; the 2019 contents use "cleanliness microbial/bioburden" and "Cleanliness – microbial".
  • "Manufacturer" uses the MDR wording; "single-use product" is a device intended to be used on one individual during a single procedure.
  • The note to "processor" refers to the MDR and to "reprocessors".

Entry-level changes in Part 1 therefore cannot be checked. In Part 2, where both editions are visible, the 2025 text drops the general "cleanliness" entry and the "surgical procedure" entries and adopts MDR wording for "manufacturer" and "single-use product". Whether Part 1 did the same has to be confirmed in the standard.

Performance levels and product areas

The framework existed in 2019: its contents show Annex E.1 "Performance levels" and E.2.2 "Critical and less critical areas", and its foreword refers to Tables 1 and 2. In the 2025 edition:

  • A critical product area (3.2) is more likely to be involved in transferring infective agents to or from the wound, for example the front and sleeves of a gown; a less critical area (3.4) is less likely.
  • Performance level (3.8) is standard or high. High performance should be considered where extensive liquid exposure, mechanical stress or longer procedures are expected.
  • Clause 4: products tested to Annex A shall meet all requirements, including Table 1 or 2, throughout their useful life. If areas are not differentiated, all areas meet critical area requirements. Use as a sterile field brings in the Table 2 drape requirements. Some requirements apply to all levels and areas.

Whether the Table 1 and 2 values are identical in both editions cannot be confirmed from the previews.

Annexes and other clauses

Part20192025
Annex A TestingA.1; A.2 (A.2.1 to A.2.8); A.3 Treatment of resultsSame headings; detail of item a) not in preview
Annex B RationalesB.2 "Cleanliness – microbial"B.2 "Microbial cleanliness"; others unchanged
Annex C Further characteristicsComfort, adhesion, liquid control, flammability, electrostatic dischargeSame
Annex DEnvironmental aspectsEnvironmental impact
Annex E GuidancePerformance levels, functional design, practical trialsSame
Annex ZADirective 93/42/EECRegulation (EU) 2017/745

Clauses 5 and 6 keep their headings and are not listed as significant changes. SUNGO's CNAS schedule numbers the seven EN 13795-1:2025 items A.2.1 to A.2.7, the same order as the seven test methods under A.2.1 to A.2.7 in the 2019 contents.

EN 13795-2:2025 (clean air suits)

Part 2 is entry 34 in Decision (EU) 2025/2078. Its foreword lists four changes: clarified testing and reporting, Annex C renamed "Environmental impact", MDR alignment, and updated references. Both previews include Clauses 2 and 3 and Table 1:

  • References: tensile moves from EN 29073-3:1992 to EN ISO 9073-3:2023; bursting from the 1999 to the 2019 edition; EN ISO 11737-1:2018 gains the A1:2021 footnote; EN ISO 22612:2005 and EN ISO 9073-10:2004 are unchanged. Neither edition cites EN ISO 22610 or EN ISO 811.
  • Table 1 (2025) has five characteristics: dry microbial penetration, microbial cleanliness, particle release, dry bursting and dry tensile strength, each with a dated method and an Annex A clause (A.2.1 to A.2.5). The 2019 table had a "Test method (for normative references see Clause 2)" column; all five methods (EN ISO 22612, EN ISO 11737-1, EN ISO 9073-10, EN ISO 13938-1, EN 29073-3) are undated, and there is no clause column.
  • Terms: a clean air suit can now include a barrier hood; "microbial cleanliness" replaces "cleanliness"; the surgical procedure entries are deleted; MDR wording is used for "manufacturer" and "single-use product".

Both editions carry the same design paragraph after Table 1, so it is not new in 2025: the Table 1 methods are material tests and design must also be considered; arm and foot openings shall be closed and a barrier hood should be worn, tucked into the neckline.

Clean air suits have no wet penetration or liquid penetration requirement, and the five EN 13795-2:2025 items in SUNGO's CNAS schedule match the 2025 Table 1.

What to do with existing 2019 reports

First check what the report is based on: which edition, which tensile method, and how wet bursting specimens were prepared. Then:

CharacteristicMethod changeSuggested approach
Dry and wet microbial penetrationNoneGap assessment against 2025 Annex A: conditions, expression and treatment of results
Liquid penetration; particle releaseNoneAs above
Microbial cleanlinessA1:2021 footnoteGap assessment, including any effect of A1:2021
Bursting, dry1999 to 2019 (minor)Gap assessment
Bursting, wetPreparation changedConsider retesting first
Tensile, dry and wetReplaced by EN ISO 9073-3:2023Consider retesting first; otherwise compare width option, tester type and 8.2 (laboratory sample)

Changes in material, layers, construction, area division, or the processing or claimed useful life of a reusable product call for new assessment or testing. The technical documentation also needs updating: Annex ZA now refers to the MDR and the labelling reference is EN ISO 20417. As checked on 22 October 2026, the UK designated list (Great Britain) showed the 2019 editions, so confirm the edition separately for the EU and Great Britain.

Accreditation scope table

Copied from the CNAS schedule (L22083) and IAS scope (TL-1019) of Shanghai SUNGO Medical Technology Co., Ltd. Item names translate the Chinese CNAS entries. All CNAS rows are effective from 9 March 2026 with an empty limitation field.

ItemBasis (clause)Notes / limitations
Gowns and drapes: microbial cleanlinessEN 13795-1:2025 A 2.1; EN ISO 11737-1:2018+A1:2021CNAS; none stated
Gowns and drapes: lintingEN 13795-1:2025 A 2.2; EN ISO 9073-10:2004CNAS; none stated
Gowns and drapes: resistance to water penetrationEN 13795-1:2025 A 2.3; EN ISO 811:2018CNAS; none stated
Gowns and drapes: bursting strength, dry and wetEN 13795-1:2025 A 2.4; EN ISO 13938-1:2019CNAS; none stated
Gowns and drapes: tensile strength, dry and wetEN 13795-1:2025 A 2.5; EN ISO 9073-3:2023CNAS; none stated
Gowns and drapes: microbial penetration, dryEN 13795-1:2025 A 2.6; EN ISO 22612:2005CNAS; none stated
Gowns and drapes: microbial penetration, wetEN 13795-1:2025 A 2.7; EN ISO 22610:2006CNAS; none stated
Clean air suits: microbial cleanlinessEN 13795-2:2025 A 2.1CNAS; none stated
Clean air suits: lintingEN 13795-2:2025 A 2.2; EN ISO 9073-10:2004CNAS; none stated
Clean air suits: bursting strength, dryEN 13795-2:2025 A 2.3; EN ISO 13938-1:2019CNAS; none stated
Clean air suits: tensile strength, dryEN 13795-2:2025 A 2.4; EN ISO 9073-3:2023CNAS; none stated
Clean air suits: microbial penetration, dryEN 13795-2:2025 A 2.5CNAS; none stated
Whole standardEN 13795-1; EN 13795-2IAS; no year; confirm the edition before an IAS report
Whole standardEN ISO 9073-3; EN 29073-3; ISO 11737-1IAS; no year

EN 13795 and the EN ISO methods above are not in the Shanghai CMA schedule. EN ISO 22610, 22612, 811, 9073-10 and 13938-1 are not listed separately in the IAS scope.

Where SUNGO tests this, and under which accreditation

Testing is done by Shanghai SUNGO Medical Technology Co., Ltd. at its laboratory at No. 958 Kangqiao East Road, Pudong, Shanghai.

  • CNAS (L22083): reports to EN 13795-1:2025 (the seven items listed) and EN 13795-2:2025 (the five items listed). The CNAS schedule lists only the 2025 editions; the 2019 editions are not in it. The certificate states that CNAS is a signatory to the ILAC and APAC arrangements.
  • IAS (TL-1019): EN 13795-1 and EN 13795-2 as whole standards without a year; confirm the edition with the laboratory before an IAS report is issued. The certificate carries the ilac-MRA mark.
  • CMA (240015340087): covers only items in its schedule and is valid only within the People's Republic of China. EN 13795 is not in the schedule, so no CMA report is possible.

Hefei SUNGO Medical Technology Co., Ltd. is a separate legal entity and its scope does not include these items. Whether an overseas regulator or notified body accepts a report depends on that body's requirements.

Preparing your request

  • The complete old report, including methods, conditions, results and treatment of results; a conclusion page alone is not enough.
  • Product type (gown, drape or clean air suit), claimed performance level, whether areas are differentiated, and the materials in each area.
  • Single-use or reusable; for reusable products, the processing method and claimed useful life.
  • Target market and edition, and whether you need a CNAS report (2025 editions) or an IAS report (edition to be confirmed with the laboratory).
  • Any changes in material, construction or process since the last test.

FAQ

Can a 2019 report still go into the CE technical documentation?

The edition harmonised under the MDR is 2025. The notified body decides whether an older report is acceptable; a common approach is a gap assessment plus retesting where needed.

Is retesting tensile and wet bursting strength enough?

That depends on the gap assessment and on whether the product has changed. The other reports still need checking against the 2025 Annex A.

Do clean air suits need wet penetration or liquid penetration tests?

Neither edition of EN 13795-2 cites EN ISO 22610 or EN ISO 811, and the 2025 Table 1 has five characteristics, matched by SUNGO's CNAS items.

Which edition does an IAS report state?

The IAS scope lists the whole standard without a year. Confirm the edition with the laboratory before ordering.

Did the performance values change?

The 2025 foreword lists no revision of performance requirements. The table values are not in the previews; refer to the standard.

To check which items in an existing report need retesting to the 2025 editions, or to arrange testing, send us the old report, a product description and the target edition, and say whether you need a CNAS or IAS report. A gap assessment of an old report is not an accredited test, and whether its conclusion is accepted is for the notified body or customer to decide. See our surgical gown and drape testing service and use the contact page to request a quote.

About SUNGO Lab: What We Test

SUNGO Lab is made up of two independent companies, Shanghai SUNGO Medical Technology Co., Ltd. and Hefei SUNGO Medical Technology Co., Ltd., and focuses on medical device testing. Our core service lines are:

  • Wheelchair and mobility aid testing (Hefei laboratory): manual and powered wheelchairs, scooters, walking aids and crutches to the ISO 7176 series (excluding Part 19 crash testing and Part 20 standing wheelchairs), ANSI/RESNA WC-1/WC-2, EN 12183, EN 12184, the GB/T 18029 series and GB/T 12996-2024. Which accreditation (CNAS, CMA or IAS) covers each standard is as listed in our certificate scopes. See Wheelchair testing for FDA 510(k) and RESNA.
  • Medical electrical safety and EMC (Hefei laboratory, IAS accredited, certificate TL-1119): IEC 60601-1, IEC 60601-1-2, IEC 60601-1-8, IEC 60601-1-11 and ISO 80601-2-69, with the corresponding Chinese standards GB 9706.1 and YY 9706.102.
  • Testing for registration in China and overseas: we plan testing to the standards your target market requires (NMPA, FDA 510(k), EU CE marking and others) and issue the test reports for your submission; whether a report is accepted is decided by the regulator.

Our Shanghai laboratory also tests medical masks, gloves, surgical gowns, sterile packaging and sterilization-related items. CNAS and IAS are both signatories to the ILAC MRA. Send your product, target markets and standards through our contact page and we will confirm which laboratory and which accredited scope covers each test.

Need testing? Tell us your product and standards

Contact us directly
Phone
+86 132 4819 8029 (Mr. Gan)+86 177 5560 4650 (Mr. Luo)
E-mail
haixiao.gan@sungoglobal.comjun.luo@sungoglobal.com
Mon–Fri 9:00-18:00
WeChat QR CodeWeChatScan to add us on WeChat
Send us a message
About your personal information
  • Who collects it: Shanghai SUNGO Medical Technology Co., Ltd., the operator of this website. If the work you ask about is carried out by Hefei SUNGO Medical Technology Co., Ltd., we pass your enquiry to that company’s contact person for the same purpose.
  • What we collect: only what you type into the form above. The website’s access logs routinely record IP address and browser type, used only for security, troubleshooting and traffic statistics. Please do not enter ID numbers, medical records or other sensitive information.
  • Why: to reply to this testing enquiry. It is not used for bulk marketing; except for passing it to Hefei SUNGO Medical Technology Co., Ltd. as described above, it is not given to anyone else.
  • How long: 12 months from the day you submit it, then it is deleted. It is stored on a server in mainland China.
  • Your rights: contact us by the phone numbers or e-mail addresses above at any time to see, correct or delete what you submitted.