GB/T 16292-2025 Cleanroom Airborne Particles: Sampling Points and Acceptance

GB/T 16292-2025 Cleanroom Airborne Particles: Sampling Points and Acceptance

Chinese sterile device manufacturers usually have cleanroom airborne particle counts measured to GB/T 16292, Test method for airborne particles in clean room (zone) of the pharmaceutical industry. GB/T 16292-2025 takes effect on 2026-11-01 and replaces the 2010 edition in full, changing the minimum number of sampling locations, the sample volume and the way results are judged. Working from both editions, this article covers sampling points, sample volume, the ≥0.5 μm and ≥5 μm sizes, evaluation, monitoring, the link to China's sterile device GMP levels, and SUNGO Shanghai's accreditation scope.

Key points

  • A method, not a set of limits: the foreword of the 2010 edition states that it only specifies the test method and does not grade cleanrooms. Clause 6.7.4 of the 2025 edition judges results against "the concentration limits specified by the relevant regulations".
  • New edition effective 2026-11-01: GB/T 16292-2025 was published on 2025-10-05 and replaces GB/T 16292-2010 in full.
  • Sampling points depend on area only: Table 1 of the 2025 edition gives the minimum number of sampling locations by area alone, with a formula above 1 000 m². Table 1 of the 2010 edition used both area and cleanliness level.
  • Sample volume is sized to catch at least 20 particles: at least 2 L sampled at each location, with a minimum single-sample time of 1 min.
  • No more UCL: the 2025 edition deletes the standard error and 95% upper confidence limit calculations. A room meets the requirement only if every sampling location is within the specified limit.
  • Levels, limits and method have different sources: process levels from the GMP appendix for sterile devices, limits from industry standards and company documents, the method from GB/T 16292.
  • What SUNGO can issue: GB/T 16292 (whole standard, no edition year) is within the IAS accreditation of SUNGO's Shanghai laboratory (TL-1019). It is not covered by CNAS or CMA, so only an IAS report can be issued.

The standard and its scope

Editions and responsible committee

GB/T 16292 is a recommended national standard. It was first published in 1996, revised in 2010 (published 2010-09-02, effective 2011-02-01) and revised again in 2025. The 2025 edition was proposed by the National Medical Products Administration (NMPA) and is under SAC/TC 106, the national technical committee for medical infusion devices. GB/T 16293-2025 (airborne microbes) and GB/T 16294-2025 (settling microbes) were published and take effect on the same dates.

Scope and normative references

Clause 1 of the 2025 edition says it describes, and applies to, testing of airborne particle concentration in pharmaceutical cleanrooms (zones). Only two documents are normatively referenced: GB/T 29024.4 (light scattering airborne particle counters for clean spaces) and GB/T 36066 (cleanrooms and associated controlled environments, testing requirements and application). Terms such as as-built, at-rest and operational are taken from GB/T 25915.1-2021.

Why device makers use a "pharmaceutical" standard

The link to sterile devices is long-standing: Annex C of YY 0033-2000 (GMP for sterile medical devices; now the recommended standard YY/T 0033-2000), "Environmental requirements and monitoring of cleanrooms (zones) for sterile medical devices", cites GB/T 16292, GB/T 16293 and GB/T 16294 (all 1996 editions at the time) as the monitoring methods for particle count, airborne microbes and settling microbes. Regional regulators cite it too: the Beijing Municipal Medical Products Administration's sterile device GMP inspection guide (2022 edition, posted 2022-04-22) says manufacturers' particle-count procedures and sampling point maps should conform to GB/T 16292 and related standards. Which edition and limits apply should be taken from the documents themselves.

What changed in 2025

The table follows the main technical changes listed in the foreword of the 2025 edition.

TopicGB/T 16292-2010GB/T 16292-2025
Minimum sampling pointsBy formula or by Table 1; Table 1 is by area and level (Class 100, 10,000, 100,000, 300,000)Table 1 by area only; formula (1) above 1 000 m²
Number of samplesSmall cleanrooms: at least 2 sampling points and at least 5 samples in totalRequirement deleted; sampling time per location added
Single sample volumeFrom Table 2, by level and particle sizeCalculated with formula (2); at least 2 L at each location
Calculation and evaluationStandard error and 95% UCL; each location mean and the UCL must not exceed the class limitConversion to particles per m³; every location must be within the limit set by the relevant regulations
MonitoringNo dedicated clauseNew Clause 7 "Monitoring" and informative Annex A

Conditions before testing

  • Personnel and instrument: testers are trained and wear cleanroom garments suited to the room's class; the counter is adjusted according to its manual, including a zero count check.
  • Environment: integrity-related parameters should be commissioned; where needed, pre-test temperature and humidity, air volume, pressure difference and filter leakage first (these are not part of the particle test itself).
  • Occupancy state: decide whether the test is as-built, at-rest (equipment installed and operating as agreed, no people) or operational (the specified number of people present, working in the agreed manner).
  • Run time: for as-built or at-rest tests, start after the HVAC system has run normally for at least 10 min in unidirectional-flow rooms and at least 30 min in non-unidirectional-flow rooms.

Number and location of sampling points

Table 1: by area

Per Clause 6.2 of the 2025 edition, the Table 1 minimum gives at least 95% confidence that at least 90% of the cleanroom does not exceed the class limit. Some examples: up to 2 m², 1 location; up to 10 m², 5; up to 52 m², 10; up to 104 m², 16; up to 1 000 m², 27. Above 1 000 m², use formula (1): NL = 27 × A / 1 000, where A is the area in m², rounded up to a whole number.

If the area falls between two rows, use the larger; for unidirectional flow use the cross-section perpendicular to the airflow, otherwise the floor area.

Where to put them

Clause 6.4: divide the room into NL sections of equal area, choose one representative location in each, and place the probe at working height or another specified position. Extra locations may be added where critical points matter. In non-unidirectional-flow rooms, locations beneath the supply outlets of non-diffusing air supply devices are not representative (Clause 6.4, item g). The 2010 edition generally placed points on a horizontal plane 0.8 m above the floor and gave layout examples in Annex A; the 2025 edition deletes that annex.

Sample volume, sampling time and the two particle sizes

Clause 6.5 sets the principle: if the concentration of the largest selected particle size were exactly at the class limit, the air sampled at each location must still be enough to detect at least 20 particles. The minimum single sample volume is Vs = 20 / Cn,m × 1 000 (formula 2), where Vs is in litres and Cn,m is the class limit for the largest particle size of interest, in particles/m³. At least 2 L must be sampled at each location, the minimum time for a single sample at each location is 1 min, and every sample at a location should have the same volume.

Table 2 of GB/T 16292-2010 gives minimum sample volumes separately for ≥0.5 μm and ≥5 μm, and at every level the volume for ≥5 μm is the larger. The first sentence of Clause 6.5 of the 2025 edition refers to the limit of "the specified cleanliness class (ISO)". When testing to the levels set in a manufacturer's documents, agree in the test plan with the laboratory how the single sample volume is determined, and refer to the standard text. Sizes and limits come from the manufacturer's documents; state them in the request.

Particle counter requirements

  • Principle: Clause 4.1 describes a light scattering counter: scattered light becomes electrical pulses, whose height indicates particle size and whose number indicates particle count.
  • Performance: Clause 4.2 calls for a stable light source, accurate flow measurement and detection, and size resolution; resolution and maximum permissible error should meet GB/T 36066.
  • Calibration: standard particles and a valid calibration certificate; interval and method per GB/T 29024.4 or applicable national metrology regulations. A note to Clause 4.2 says that where a counter cannot be calibrated by the method in GB/T 29024.4, the reason for using it is recorded in the test report.
  • Sampling system: Clause 6.6 calls for an isokinetic probe, with direct sampling preferred. Where tubing is used, consider the effect of its material, inner wall, length, diameter, position relative to the instrument and bend radius, especially for particles ≥1 μm; keep it within the length and diameter the instrument manufacturer recommends, and as short and straight as possible.
  • On site: clean or disinfect the instrument before entry; point the probe into unidirectional airflow, or straight up where flow direction is unpredictable; an abnormal count from unusual conditions may be excluded after verification, noted in the report and resampled.

Calculating and evaluating results

2025 edition

Under Clause 6.7, record each sample result; where a location is sampled two or more times, take the mean particle count Xi; convert it to particles per cubic metre with formula (4), Ci = Xi × 1 000 / Vi, where Vi is the single sample volume in litres. Clause 6.7.4: the cleanroom is regarded as meeting the specified classification only if the concentration at every sampling location is within the limit set by the relevant regulations. Out-of-limit counts are investigated, with the findings and corrective actions stated in the report.

The 2010 edition's 95% UCL

The 2010 edition calculated the mean at each location, the overall mean M and its standard error SE, then the 95% upper confidence limit UCL = M + t × SE, with t taken from Table 3 according to the number of locations. The UCL was needed for 2 to 9 locations, not for more than 9. Each location mean and the UCL both had to be within the class limit.

In practice, reports to the 2010 edition include a UCL where there were 2 to 9 locations, while reports to the 2025 edition no longer calculate one, so take care when trending across the change and state the edition in contracts and procedures. Clause 6.8 lists report contents, including the acceptance basis, occupancy state, a location map, particle sizes, calibration date and every location's result.

How this fits the cleanliness levels in the GMP appendix for sterile devices

An NMPA notice dated 2026-09-14 (Guo Yao Jian Xie Guan [2026] No. 14) states that China's revised GMP for Medical Devices takes effect on 2026-11-01, and that from then sterile and certain other device categories must comply with both the revised GMP and the corresponding current GMP appendix (for sterile devices, former CFDA Announcement No. 101 of 2015). A new GMP inspection guideline takes effect the same day, and the GMP on-site inspection guideline issued under Shi Yao Jian Xie Jian [2015] No. 218 (Attachment 1 of that document) is repealed; guidelines for sterile and other categories will be revised and issued separately. The table follows Attachment 2, the on-site inspection guideline for sterile devices, using its item numbers; a revised text will prevail once issued.

ItemProducts and areasCleanliness level
2.10.1Sterile devices implanted or introduced into blood vessels, and sterile devices or individually packaged accessories that need further processing in a local Class 100 zone within Class 10,000: areas for final cleaning, assembly, primary packaging and sealing, and for processing parts that are not cleanedNot lower than Class 10,000
2.11.1Sterile devices or accessories in direct or indirect contact with blood, the bone marrow cavity or non-natural body passages; same areasNot lower than Class 100,000
2.12.1Sterile devices or accessories in contact with injured body surfaces and mucosa; same areasNot lower than Class 300,000
2.13.1Primary packaging not in direct contact with the device's use surface (packaging in direct contact and used without cleaning follows the product's own level)Not lower than Class 300,000
2.14.1Sterile devices (including medical materials) that require, or are made by, aseptic processingLocal Class 100 within Class 10,000
2.15.1Cleanroom garment washing and drying rooms, cleaning tool rooms, and final cleaning and disinfection of dedicated workstation tools; folding and post-sterilization storage of sterile garmentsThe former may be one level below the production area but not lower than Class 300,000; the latter at Class 10,000

Item 2.17.1 of the same guideline requires cleanliness indicators to meet the relevant medical device industry standards; item 8.9.1 requires periodic testing or monitoring of particles, airborne or settling microbes and other parameters to those standards, with records kept. For particle testing, that means three steps:

  1. Levels: assign a level to each room or zone from the table above and the manufacturer's documents.
  2. Limits: the ≥0.5 μm and ≥5 μm limits for each level, and the occupancy state they apply to, come from the industry standard the manufacturer has selected and its own documents. They are not restated here; refer to the original texts.
  3. Measure and compare: set locations, sample volume and per-location concentration per GB/T 16292, then compare each location with the limit from step 2.

Routine monitoring versus periodic classification testing

The 2025 edition separates classification testing (Clause 6), which assesses cleanliness by measuring particle concentration, from monitoring (Clause 7): measurement to a defined method and plan to verify facility performance, whether continuous, intermittent or periodic.

AspectClassification test (Clause 6)Monitoring (Clause 7)
Sampling locationsFrom Table 1 or formula (1), equal-area sectionsSet by risk assessment, focused on critical process positions
FrequencyPeriodic, based on risk assessment; may be extended if continuous or frequent monitoring stays within limitsPer a written plan that is approved and periodically reviewed
LimitsConcentration limits set by the relevant regulationsMonitoring limits, with alert and action levels
DeviationsInvestigate; state findings and corrective actions in the reportInvestigate and correct; if the correction has a major effect, repeat classification per Clause 6 and resume monitoring once it passes

Clause 7.5 lists priority positions such as near open product, at critical steps and where people and materials move often.

For example, the Beijing Municipal Medical Products Administration's cleanroom inspection guide (2023 edition, posted 2023-12-08) says routine environmental monitoring should be done by the manufacturer itself, not contracted out, while manufacturers should periodically commission a qualified testing body. Other regions may differ, and what "qualified" means is for the local regulator to decide. GB/T 16292 is not on SUNGO's CMA schedule, so SUNGO can only issue an IAS report; check with the local regulator before relying on it here.

Accreditation scope

The four rows below are the entries in SUNGO Shanghai's IAS scope (TL-1019) that relate to this article.

ItemClauseNotes / limitation
GB/T 16292 Test method for airborne particles in clean room (zone) of the pharmaceutical industryWhole standardIAS, no edition year; no limitation listed
GB/T 16293 Test method for airborne microbe in clean room (zone) of the pharmaceutical industryWhole standardIAS, no edition year; no limitation listed
GB/T 16294 Test method for settling microbe in clean room (zone) of the pharmaceutical industryWhole standardIAS, no edition year; no limitation listed
YY 0033 Good manufacture practice for sterile medical devicesAnnex CIAS; Accredited only for Annex C

These four are not on SUNGO Shanghai's CNAS or CMA certificates, and the Hefei laboratory's certificates do not cover cleanroom testing. The GB/T 25915 and ISO 14644 series are not within the scope of either site.

Where SUNGO performs it and under which accreditation

  • Entity: Shanghai SUNGO Medical Technology Co., Ltd., laboratory at 958 Kangqiao East Road, Pudong, Shanghai. Hefei SUNGO Medical Technology Co., Ltd. is a separate legal entity.
  • Accreditation: IAS only (TL-1019). An IAS-accredited report can be issued; a CNAS or CMA report cannot.
  • Edition: the IAS scope carries no edition year. Confirm the edition (2025 or 2010) with the laboratory before ordering an IAS report.
  • Location: GB/T 16292 testing has to be done in the cleanroom being tested; timing and occupancy state are agreed at quotation.
  • Use of the report: whether an IAS report meets a regulator's or auditor's requirements for testing bodies depends on their rules; check in advance.

Preparing for the test

  • A layout showing the area and specified level of each room or zone, supply and return air positions, and any unidirectional-flow supply face.
  • The acceptance basis: which document sets the levels and limits, and which particle sizes to measure (for example ≥0.5 μm and ≥5 μm).
  • The edition to apply, GB/T 16292-2025 or the 2010 edition, confirmed with the laboratory.
  • The occupancy state; for operational tests, the number and positions of people and running equipment.
  • Existing pre-test records for temperature and humidity, air volume, pressure difference and filter leakage.
  • Site conditions: critical steps and open-product positions, personnel and material routes, HVAC run schedule, gowning and entry procedures.

FAQ

Can testing still follow GB/T 16292-2010 from 2026-11-01?

The 2025 edition replaces the 2010 edition in full from that date. If your documents or contract still specify the 2010 edition, confirm with the laboratory before ordering whether an IAS report can be issued to it.

Is one sampling location enough for a very small room?

Under Table 1 of the 2025 edition, the minimum for up to 2 m² is one location. The 2010 rule of at least 2 locations and 5 samples for small cleanrooms has been deleted; extra locations can still be added at critical points.

Can SUNGO report to the ISO 14644 series?

Neither the ISO 14644 series nor the GB/T 25915 series is within SUNGO's accreditation scope; what SUNGO can issue is an IAS report to GB/T 16292.

Can airborne and settling microbes be tested at the same time?

GB/T 16293 (airborne microbes) and GB/T 16294 (settling microbes) are also within the Shanghai IAS scope (whole standards) and can be included in the same request; a separate article covers them.

Requesting a quote

Please send the items listed under "Preparing for the test" and the site address, so sampling points and the site visit can be planned. Service page: Other Medical Device Testing. Submit your request through the contact page.

About SUNGO Lab: What We Test

SUNGO Lab is made up of two independent companies, Shanghai SUNGO Medical Technology Co., Ltd. and Hefei SUNGO Medical Technology Co., Ltd., and focuses on medical device testing. Our core service lines are:

  • Wheelchair and mobility aid testing (Hefei laboratory): manual and powered wheelchairs, scooters, walking aids and crutches to the ISO 7176 series (excluding Part 19 crash testing and Part 20 standing wheelchairs), ANSI/RESNA WC-1/WC-2, EN 12183, EN 12184, the GB/T 18029 series and GB/T 12996-2024. Which accreditation (CNAS, CMA or IAS) covers each standard is as listed in our certificate scopes. See Wheelchair testing for FDA 510(k) and RESNA.
  • Medical electrical safety and EMC (Hefei laboratory, IAS accredited, certificate TL-1119): IEC 60601-1, IEC 60601-1-2, IEC 60601-1-8, IEC 60601-1-11 and ISO 80601-2-69, with the corresponding Chinese standards GB 9706.1 and YY 9706.102.
  • Testing for registration in China and overseas: we plan testing to the standards your target market requires (NMPA, FDA 510(k), EU CE marking and others) and issue the test reports for your submission; whether a report is accepted is decided by the regulator.

Our Shanghai laboratory also tests medical masks, gloves, surgical gowns, sterile packaging and sterilization-related items. CNAS and IAS are both signatories to the ILAC MRA. Send your product, target markets and standards through our contact page and we will confirm which laboratory and which accredited scope covers each test.

Need testing? Tell us your product and standards

Contact us directly
Phone
+86 132 4819 8029 (Mr. Gan)+86 177 5560 4650 (Mr. Luo)
E-mail
haixiao.gan@sungoglobal.comjun.luo@sungoglobal.com
Mon–Fri 9:00-18:00
WeChat QR CodeWeChatScan to add us on WeChat
Send us a message
About your personal information
  • Who collects it: Shanghai SUNGO Medical Technology Co., Ltd., the operator of this website. If the work you ask about is carried out by Hefei SUNGO Medical Technology Co., Ltd., we pass your enquiry to that company’s contact person for the same purpose.
  • What we collect: only what you type into the form above. The website’s access logs routinely record IP address and browser type, used only for security, troubleshooting and traffic statistics. Please do not enter ID numbers, medical records or other sensitive information.
  • Why: to reply to this testing enquiry. It is not used for bulk marketing; except for passing it to Hefei SUNGO Medical Technology Co., Ltd. as described above, it is not given to anyone else.
  • How long: 12 months from the day you submit it, then it is deleted. It is stored on a server in mainland China.
  • Your rights: contact us by the phone numbers or e-mail addresses above at any time to see, correct or delete what you submitted.